Characterization Metric Report: Science Pipelines Version 13.0

Measured using validation_data_hsc, which consists of 8 HSC engineering images: 4 r-band, 2 i’-band, and 2 y-band. Measurements were made on individual, separately-processed, single-frame images: Jointcal and/or meas_mosaic were not run. For comparison, we provide the SRD required “minimum” value of each metric as defined in the Science Requirements Document (LPM-17), and, where available, the target for this release as defined in the Data Management Development Milestone Roadmap (LDM-240). All values were computed using the examples/runHscTest.sh script in the validate_drp package.

Photometric Performance

Submitted by Michael Wood-Vasey

procCalRep corresponds to requirement OSS-REQ-0275 (defined in LSE-30). All other photometric performance metrics follow LSS-REQ-0093 (LSE-29) and LPM-17 table 14.

Metric Unit SRD Requirement Release 13 Target Value Comments
procCalRep mmag 13 10.0 Need simulations
PA1 (g band) mmag 8 12.0 No data
PA1 (r band) mmag 8 12.0 14.3  
PA1 (i band) mmag 8 12.0 12.0  
PF1 (g band) % 20 No data
PF1 (r band) % 20 30.6  
PF1 (i band) % 20 18.2  
PA2 (g band) mmag 15 No data
PA2 (r band) mmag 15 19.6  
PA2 (i band) mmag 15 18.2  
PA1 (u band) mmag 12 13.0 No data
PA1 (z band) mmag 12 13.0 No data
PA1 (y band) mmag 12 13.0 24.3  
PF1 (u band) % 20 No data
PF1 (z band) % 20 No data
PF1 (y band) % 20 36.9  
PA2 (u band) mmag 22.5 No data
PA2 (z band) mmag 22.5 No data
PA2 (y band) mmag 22.5 33.6  

Astrometric Performance

Submitted by Michael Wood-Vasey

The following metrics are defined following LSR-REQ-0094 (LSE-29) and LPM-17 table 18.

Metric Unit SRD Requirement Release 13 Target Value
AM1 (r-band) mas 20 50.0 6.5
AM1 (i-band) mas 20 50.0 10.5
AF1 (r-band) % 20 0.27
AF1 (i-band) % 20 0.69
AD1 (r-band) mas 40 6.5
AD1 (i-band) mas 40 7.5
AM2 (r-band) mas 20 50.0 6.5
AM2 (i-band) mas 20 50.0 10.5
AF2 (r-band) % 20 0.47
AF2 (i-band) % 20 0.67
AD2 (r-band) mas 40 6.6
AD2 (i-band) mas 40 7.3

Ellipticity Correlations

Submitted by Michael Wood-Vasey

The following metrics are defined following LSR-REQ-0097 (LSE-29) and LPM-17 table 27.

Metric Unit SRD Requirement Release 13 Target Value
TE1 (r-band) 3×105 1×103 7.9×107
TE1 (i-band) 3×105 1×103 1.9×106
TE2 (r-band) 3×107 1×103 1.8×106
TE2 (i-band) 3×107 1×103 3.0×107

Computational Performance

Computational performance metrics were not re-measured for this release. We expect no significant changes relative to the report on version 12.