ImsimTranslator¶
-
class
lsst.obs.lsst.translators.
ImsimTranslator
(header, filename=None)¶ Bases:
lsst.obs.lsst.translators.lsstsim.LsstSimTranslator
Metadata translation class for ImSim headers
Attributes Summary
cameraPolicyFile
detectorMapping
detectorSerials
name
Name of this translation class supported_instrument
translators
Methods Summary
can_translate
(header[, filename])Indicate whether this translation class can translate the supplied header. can_translate_with_options
(header, options)Helper method for can_translate
allowing options.cards_used
()Cards used during metadata extraction. compute_detector_exposure_id
(exposure_id, …)Compute the detector exposure ID from detector number and exposure ID. compute_detector_info_from_serial
(…)Helper method to return the detector information from the serial. compute_detector_num_from_name
(…)Helper method to return the detector number from the name. compute_exposure_id
(dayobs, seqnum)Helper method to calculate the AuxTel exposure_id. defined_in_this_class
(name)Report if the specified class attribute is defined specifically in this class. detector_mapping
()Returns the mapping of full name to detector ID and serial. detector_serials
()Obtain the mapping of detector serial to detector group, name, and number. determine_translator
(header[, filename])Determine a translation class by examining the header quantity_from_card
(keywords, unit[, …])Calculate a Astropy Quantity from a header card and a unit. to_altaz_begin
()to_boresight_airmass
()to_boresight_rotation_angle
()Angle of the instrument in boresight_rotation_coord frame. to_boresight_rotation_coord
()Coordinate frame of the instrument rotation angle (options: sky, unknown). to_dark_time
()Duration of the exposure with shutter closed (seconds). to_datetime_begin
()to_datetime_end
()to_detector_exposure_id
()to_detector_group
()Collection name of which this detector is a part. to_detector_name
()Name of the detector within the instrument (might not be unique). to_detector_num
()to_detector_serial
()Serial number/string associated with this detector. to_exposure_id
()Unique (with instrument) integer identifier for this observation. to_exposure_time
()Duration of the exposure with shutter open (seconds). to_instrument
()The instrument used to observe the exposure. to_location
()to_object
()Object of interest or field name. to_observation_id
()Label uniquely identifying this observation (can be related to ‘exposure_id’). to_observation_type
()to_physical_filter
()The bandpass filter used for this observation. to_pressure
()Atmospheric pressure outside the dome. to_relative_humidity
()Relative humidity outside the dome. to_science_program
()Observing program (survey or proposal) identifier. to_telescope
()to_temperature
()Temperature outside the dome. to_tracking_radec
()to_visit_id
()ID of the Visit this Exposure is associated with. validate_value
(value, default[, minimum, …])Validate the supplied value, returning a new value if out of range Attributes Documentation
-
cameraPolicyFile
= 'policy/imsim.yaml'¶
-
detectorMapping
= None¶
-
detectorSerials
= None¶
-
name
= 'ImSim'¶ Name of this translation class
-
supported_instrument
= None¶
-
translators
= {'DECam': <class 'astro_metadata_translator.translators.decam.DecamTranslator'>, 'HSC': <class 'astro_metadata_translator.translators.hsc.HscTranslator'>, 'ImSim': <class 'lsst.obs.lsst.translators.imsim.ImsimTranslator'>, 'LSST-TS3': <class 'lsst.obs.lsst.translators.ts3.LsstTS3Translator'>, 'LSST-TS8': <class 'lsst.obs.lsst.translators.ts8.LsstTS8Translator'>, 'LSST-UCDCam': <class 'lsst.obs.lsst.translators.lsst_ucdcam.LsstUCDCamTranslator'>, 'LSSTAuxTel': <class 'lsst.obs.lsst.translators.auxTel.LsstAuxTelTranslator'>, 'LSSTCam': <class 'lsst.obs.lsst.translators.lsstCam.LsstCamTranslator'>, 'MegaPrime': <class 'astro_metadata_translator.translators.megaprime.MegaPrimeTranslator'>, 'PhoSim': <class 'lsst.obs.lsst.translators.phosim.PhosimTranslator'>, 'SuprimeCam': <class 'astro_metadata_translator.translators.suprimecam.SuprimeCamTranslator'>}¶
Methods Documentation
-
classmethod
can_translate
(header, filename=None)¶ Indicate whether this translation class can translate the supplied header.
There is no
INSTRUME
header in ImSim data. Instead we use theTESTTYPE
header.Parameters: Returns:
-
classmethod
can_translate_with_options
(header, options, filename=None)¶ Helper method for
can_translate
allowing options.Parameters: - header :
dict
-like Header to convert to standardized form.
- options :
dict
Headers to try to determine whether this header can be translated by this class. If a card is found it will be compared with the expected value and will return that comparison. Each card will be tried in turn until one is found.
- filename :
str
, optional Name of file being translated.
Returns: Notes
Intended to be used from within
can_translate
implementations for specific translators. Is not intended to be called directly fromdetermine_translator
.- header :
-
cards_used
()¶ Cards used during metadata extraction.
Returns:
-
static
compute_detector_exposure_id
(exposure_id, detector_num)¶ Compute the detector exposure ID from detector number and exposure ID.
This is a helper method to allow code working outside the translator infrastructure to use the same algorithm.
Parameters: Returns: - detector_exposure_id :
int
The calculated ID.
- detector_exposure_id :
-
classmethod
compute_detector_info_from_serial
(detector_serial)¶ Helper method to return the detector information from the serial.
Parameters: - detector_serial :
str
Detector serial ID.
Returns: - detector_serial :
-
classmethod
compute_detector_num_from_name
(detector_group, detector_name)¶ Helper method to return the detector number from the name.
Parameters: Returns: - num :
int
Detector number.
- num :
-
static
compute_exposure_id
(dayobs, seqnum)¶ Helper method to calculate the AuxTel exposure_id.
Parameters: Returns: - exposure_id :
int
Exposure ID in form YYYYMMDDnnnnn form.
- exposure_id :
-
classmethod
defined_in_this_class
(name)¶ Report if the specified class attribute is defined specifically in this class.
Parameters: - name :
str
Name of the attribute to test.
Returns: - in_class :
bool
True
if there is a attribute of that name defined in this specific subclass.False
if the method is not defined in this specific subclass but is defined in a parent class. ReturnsNone
if the attribute is not defined anywhere in the class hierarchy (which can happen if translators have typos in their mapping tables).
Notes
Retrieves the attribute associated with the given name. Then looks in all the parent classes to determine whether that attribute comes from a parent class or from the current class. Attributes are compared using
id()
.- name :
-
classmethod
detector_mapping
()¶ Returns the mapping of full name to detector ID and serial.
Returns: Raises: - ValueError
Raised if no camera policy file has been registered with this translation class.
Notes
Will construct the mapping if none has previously been constructed.
-
classmethod
detector_serials
()¶ Obtain the mapping of detector serial to detector group, name, and number.
Returns:
-
classmethod
determine_translator
(header, filename=None)¶ Determine a translation class by examining the header
Parameters: Returns: - translator :
MetadataTranslator
Translation class that knows how to extract metadata from the supplied header.
Raises: - ValueError
None of the registered translation classes understood the supplied header.
- translator :
-
quantity_from_card
(keywords, unit, default=None, minimum=None, maximum=None, checker=None)¶ Calculate a Astropy Quantity from a header card and a unit.
Parameters: - keywords :
str
orlist
ofstr
Keyword to use from header. If a list each keyword will be tried in turn until one matches.
- unit :
astropy.units.UnitBase
Unit of the item in the header.
- default :
float
, optional Default value to use if the header value is invalid. Assumed to be in the same units as the value expected in the header. If None, no default value is used.
- minimum :
float
, optional Minimum possible valid value, optional. If the calculated value is below this value, the default value will be used.
- maximum :
float
, optional Maximum possible valid value, optional. If the calculated value is above this value, the default value will be used.
- checker :
function
, optional Callback function to be used by the translator method in case the keyword is not present. Function will be executed as if it is a method of the translator class. Running without raising an exception will allow the default to be used. Should usually raise
KeyError
.
Returns: - q :
astropy.units.Quantity
Quantity representing the header value.
Raises: - KeyError
The supplied header key is not present.
- keywords :
-
to_altaz_begin
()¶
-
to_boresight_airmass
()¶
-
to_boresight_rotation_angle
()¶ Angle of the instrument in boresight_rotation_coord frame.
Returns: - translation :
astropy.coordinates.Angle
Translated value derived from the header.
- translation :
-
to_boresight_rotation_coord
()¶ Coordinate frame of the instrument rotation angle (options: sky, unknown).
Returns: - translation :
str
Translated property.
- translation :
-
to_dark_time
()¶ Duration of the exposure with shutter closed (seconds).
Returns: - translation :
astropy.units.Quantity
Translated value derived from the header.
- translation :
-
to_datetime_begin
()¶
-
to_datetime_end
()¶
-
to_detector_exposure_id
()¶
-
to_detector_group
()¶ Collection name of which this detector is a part. Can be None if there are no detector groupings.
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_detector_name
()¶ Name of the detector within the instrument (might not be unique).
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_detector_num
()¶
-
to_detector_serial
()¶ Serial number/string associated with this detector.
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_exposure_id
()¶ Unique (with instrument) integer identifier for this observation.
Returns: - translation :
int
Translated value derived from the header.
- translation :
-
to_exposure_time
()¶ Duration of the exposure with shutter open (seconds).
Returns: - translation :
astropy.units.Quantity
Translated value derived from the header.
- translation :
-
to_instrument
()¶ The instrument used to observe the exposure.
Returns: - translation :
str
Translated property.
- translation :
-
to_location
()¶
-
to_observation_id
()¶ Label uniquely identifying this observation (can be related to ‘exposure_id’).
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_observation_type
()¶
-
to_physical_filter
()¶ The bandpass filter used for this observation.
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_pressure
()¶ Atmospheric pressure outside the dome.
Returns: - translation :
astropy.units.Quantity
Translated property.
- translation :
-
to_relative_humidity
()¶ Relative humidity outside the dome.
Returns: - translation :
float
Translated property.
- translation :
-
to_science_program
()¶ Observing program (survey or proposal) identifier.
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_telescope
()¶
-
to_temperature
()¶ Temperature outside the dome.
Returns: - translation :
astropy.units.Quantity
Translated property.
- translation :
-
to_tracking_radec
()¶
-
to_visit_id
()¶ ID of the Visit this Exposure is associated with.
Science observations should essentially always be associated with a visit, but calibration observations may not be.
Returns: - translation :
int
Translated value derived from the header.
- translation :
-
static
validate_value
(value, default, minimum=None, maximum=None)¶ Validate the supplied value, returning a new value if out of range
Parameters: - value :
float
Value to be validated.
- default :
float
Default value to use if supplied value is invalid or out of range. Assumed to be in the same units as the value expected in the header.
- minimum :
float
Minimum possible valid value, optional. If the calculated value is below this value, the default value will be used.
- maximum :
float
Maximum possible valid value, optional. If the calculated value is above this value, the default value will be used.
Returns: - value :
float
Either the supplied value, or a default value.
- value :
-