DiaObjectCalculationPlugin¶
- 
class lsst.ap.association.DiaObjectCalculationPlugin(config, name, metadata)¶
- Bases: - lsst.meas.base.CatalogCalculationPlugin- Base class for DIA catalog calculation plugins. - Task follows CatalogCalculationPlugin with modifications for use in AP. - Parameters: - config : DiaObjectCalculationPlugin.ConfigClass
- Plugin configuration. 
- name : str
- The string the plugin was registered with. 
- metadata : lsst.daf.base.PropertySet
- Plugin metadata that will be attached to the output catalog 
 - Attributes Summary - APCORR_ORDER- CENTROID_ORDER- DEFAULT_CATALOGCALCULATION- FLUX_MOMENTS_CALCULATED- Add order after flux means and stds are calculated. - FLUX_ORDER- SHAPE_ORDER- inputCols- DiaObject column names required by the plugin in order to run and complete its calculation. - outputCols- DiaObject column names output by the plugin. - plugType- Does the plugin operate on a single source or the whole catalog ( - str)? If the plugin operates on a single source at a time, this should be set to- "single"; if it expects the whoe catalog, to- "multi".- registry- List of available plugins ( - lsst.meas.base.PluginRegistry).- Methods Summary - calculate(diaObject, diaSources[, …])- Perform the calculation specified by this plugin. - fail(measRecord[, error])- Record a failure of the - measureor- measureNmethod.- getExecutionOrder()- Used to set the relative order of plugin execution. - getLogName()- getTransformClass()- Get the measurement transformation appropriate to this plugin. - Attributes Documentation - 
APCORR_ORDER= 3.0¶
 - 
CENTROID_ORDER= 0.0¶
 - 
DEFAULT_CATALOGCALCULATION= 4.0¶
 - 
FLUX_MOMENTS_CALCULATED= 5.0¶
- Add order after flux means and stds are calculated. 
 - 
FLUX_ORDER= 2.0¶
 - 
SHAPE_ORDER= 1.0¶
 - 
inputCols= []¶
- DiaObject column names required by the plugin in order to run and complete its calculation. DiaCalculationTask should raise an error is a plugin is instantiated without the needed column available. Input columns should be defined in the DPDD/cat/Ppdb schema. Filter dependent columns should be specified without the filter name perpended to them. eg - PSFluxMeaninstead of- uPSFluxMean.
 - 
outputCols= []¶
- DiaObject column names output by the plugin. DiaCalculationTask should raise an error if another pluging is run output to the same column. Output columns should be defined in the DPDD/cat/Ppdb schema. Filter dependent columns should be specified without the filter name perpended to them. eg - PSFluxMeaninstead of- uPSFluxMean.
 - 
plugType= 'single'¶
- Does the plugin operate on a single source or the whole catalog ( - str)? If the plugin operates on a single source at a time, this should be set to- "single"; if it expects the whoe catalog, to- "multi". If the plugin is of type- "multi", the- failmethod must be implemented to accept the whole catalog. If the plugin is of type- "single",- failshould accept a single source record.
 - 
registry= <lsst.meas.base.pluginRegistry.PluginRegistry object>¶
- List of available plugins ( - lsst.meas.base.PluginRegistry).
 - Methods Documentation - 
calculate(diaObject, diaSources, filterDiaFluxes=None, filterName=None, **kwargs)¶
- Perform the calculation specified by this plugin. - This method can either be used to operate on a single catalog record or a whole catalog, populating it with the output defined by this plugin. - Note that results may be added to catalog records as new columns, or may result in changes to existing values. - Parameters: - diaObject : dict
- Summary object to store values in. 
- diaSources : pandas.DataFrame
- DataFrame representing all diaSources associated with this diaObject. 
- filterDiaFluxes : pandas.DataFrame
- DataFrame representing diaSources associated with this diaObject that are observed in the band pass - filterName.
- filterName : str
- Simple name of the filter for the flux being calculated. 
- **kwargs
- Any additional keyword arguments that may be passed to the plugin. 
 
- diaObject : 
 - 
fail(measRecord, error=None)¶
- Record a failure of the - measureor- measureNmethod.- Parameters: - measRecord : lsst.afw.table.SourceRecord
- Table record describing the source being measured. 
- error : MeasurementError, optional
- Only provided if the measurement failed due to a - MeasurementErrorbeing raised; otherwise, will be- None.
 - Notes - When the plugin raises an exception, framework will call - BasePlugin.failto allow the plugin to set its failure flag field(s). When- BasePlugin.measureNraises an exception,- BasePlugin.failwill be called repeatedly with all the records that were being measured.- If the exception is an - MeasurementError, it will be passed as the error argument; in all other cases the error argument will be- None, and the failure will be logged by the measurement framework as a warning.
- measRecord : 
 - 
classmethod getExecutionOrder()¶
- Used to set the relative order of plugin execution. - The values returned by - getExecutionOrderare compared across all plugins, and smaller numbers run first.- Notes - CatalogCalculationPlugins must run with- BasePlugin.DEFAULT_CATALOGCALCULATIONor higher.- All plugins must implement this method with an appropriate run level 
 - 
getLogName()¶
 - 
static getTransformClass()¶
- Get the measurement transformation appropriate to this plugin. - This returns a subclass of - transforms.MeasurementTransform, which may be instantiated with details of the algorithm configuration and then called with information about calibration and WCS to convert from raw measurement quantities to calibrated units. Calibrated data is then provided in a separate output table.- Notes - By default, we copy everything from the input to the output without transformation. 
 
- config :