ForcedTransformedCentroidPlugin¶
-
class
lsst.meas.base.
ForcedTransformedCentroidPlugin
(config, name, schemaMapper, metadata)¶ Bases:
lsst.meas.base.ForcedPlugin
Record the transformation of the reference catalog centroid.
The centroid recorded in the reference catalog is tranformed to the measurement coordinate system and stored.
Parameters: - config :
ForcedTransformedCentroidConfig
Plugin configuration
- name :
str
Plugin name
- schemaMapper :
lsst.afw.table.SchemaMapper
A mapping from reference catalog fields to output catalog fields. Output fields are added to the output schema.
- metadata :
lsst.daf.base.PropertySet
Plugin metadata that will be attached to the output catalog.
Notes
This is used as the slot centroid by default in forced measurement, allowing subsequent measurements to simply refer to the slot value just as they would in single-frame measurement.
Attributes Summary
APCORR_ORDER
CENTROID_ORDER
DEFAULT_CATALOGCALCULATION
FLUX_ORDER
SHAPE_ORDER
registry
Methods Summary
fail
(measRecord[, error])Record a failure of the measure
ormeasureN
method.getExecutionOrder
()Get the relative execution order of this plugin. getLogName
()getTransformClass
()Get the measurement transformation appropriate to this plugin. measure
(measRecord, exposure, refRecord, refWcs)Measure the properties of a source given an image and a reference. measureN
(measCat, exposure, refCat, refWcs)Measure the properties of blended sources from image & reference. Attributes Documentation
-
APCORR_ORDER
= 3.0¶
-
CENTROID_ORDER
= 0.0¶
-
DEFAULT_CATALOGCALCULATION
= 4.0¶
-
FLUX_ORDER
= 2.0¶
-
SHAPE_ORDER
= 1.0¶
-
registry
= <lsst.meas.base.pluginRegistry.PluginRegistry object>¶
Methods Documentation
-
fail
(measRecord, error=None)¶ Record a failure of the
measure
ormeasureN
method.Parameters: - measRecord :
lsst.afw.table.SourceRecord
Table record describing the source being measured.
- error :
MeasurementError
, optional Only provided if the measurement failed due to a
MeasurementError
being raised; otherwise, will beNone
.
Notes
When the plugin raises an exception, framework will call
BasePlugin.fail
to allow the plugin to set its failure flag field(s). WhenBasePlugin.measureN
raises an exception,BasePlugin.fail
will be called repeatedly with all the records that were being measured.If the exception is an
MeasurementError
, it will be passed as the error argument; in all other cases the error argument will beNone
, and the failure will be logged by the measurement framework as a warning.- measRecord :
-
classmethod
getExecutionOrder
()¶ Get the relative execution order of this plugin.
Must be reimplemented as a class method by concrete derived classes.
-
getLogName
()¶
-
static
getTransformClass
()¶ Get the measurement transformation appropriate to this plugin.
This returns a subclass of
transforms.MeasurementTransform
, which may be instantiated with details of the algorithm configuration and then called with information about calibration and WCS to convert from raw measurement quantities to calibrated units. Calibrated data is then provided in a separate output table.Notes
By default, we copy everything from the input to the output without transformation.
-
measure
(measRecord, exposure, refRecord, refWcs)¶ Measure the properties of a source given an image and a reference.
Parameters: - exposure :
lsst.afw.image.ExposureF
The pixel data to be measured, together with the associated PSF, WCS, etc. All other sources in the image should have been replaced by noise according to deblender outputs.
- measRecord :
lsst.afw.table.SourceRecord
Record describing the object being measured. Previously-measured quantities will be retrieved from here, and it will be updated in-place with the outputs of this plugin.
- refRecord :
lsst.afw.table.SimpleRecord
Additional parameters to define the fit, as measured elsewhere.
- refWcs :
lsst.afw.geom.SkyWcs
orlsst.afw.geom.Angle
The coordinate system for the reference catalog values. An
Angle
may be passed, indicating that a local tangent WCS should be created for each object using the given angle as a pixel scale.
Notes
In the normal mode of operation, the source centroid will be set to the WCS-transformed position of the reference object, so plugins that only require a reference position should not have to access the reference object at all.
- exposure :
-
measureN
(measCat, exposure, refCat, refWcs)¶ Measure the properties of blended sources from image & reference.
This operates on all members of a blend family at once.
Parameters: - exposure :
lsst.afw.image.ExposureF
The pixel data to be measured, together with the associated PSF, WCS, etc. Sources not in the blended hierarchy to be measured should have been replaced with noise using deblender outputs.
- measCat :
lsst.afw.table.SourceCatalog
Catalog describing the objects (and only those objects) being measured. Previously-measured quantities will be retrieved from here, and it will be updated in-place with the outputs of this plugin.
- refCat :
lsst.afw.table.SimpleCatalog
Additional parameters to define the fit, as measured elsewhere. Ordered such that
zip(measCat, refcat)
may be used.- refWcs :
lsst.afw.geom.SkyWcs
orlsst.afw.geom.Angle
The coordinate system for the reference catalog values. An
Angle
may be passed, indicating that a local tangent WCS should be created for each object using the given angle as a pixel scale.
Notes
In the normal mode of operation, the source centroids will be set to the WCS-transformed position of the reference object, so plugins that only require a reference position should not have to access the reference object at all.
- exposure :
- config :