Instrument¶
-
class
lsst.pipe.base.
Instrument
(collection_prefix: Optional[str] = None)¶ Bases:
object
Base class for instrument-specific logic for the Gen3 Butler.
Parameters: - collection_prefix :
str
, optional Prefix for collection names to use instead of the intrument’s own name. This is primarily for use in simulated-data repositories, where the instrument name may not be necessary and/or sufficient to distinguish between collections.
Notes
Concrete instrument subclasses must have the same construction signature as the base class.
Attributes Summary
configPaths
Paths to config files to read for specific Tasks. policyName
Instrument specific name to use when locating a policy or configuration file in the file system. Methods Summary
applyConfigOverrides
(name, config)Apply instrument-specific overrides for a task config. formatCollectionTimestamp
(timestamp, …)Format a timestamp for use in a collection name. fromName
(name, registry, collection_prefix)Given an instrument name and a butler registry, retrieve a corresponding instantiated instrument object. from_string
(name, registry, collection_prefix)Return an instance from the short name or class name. getName
()Return the short (dimension) name for this instrument. getRawFormatter
(dataId, Mapping[str, Any]])Return the Formatter class that should be used to read a particular raw file. importAll
(registry)Import all the instruments known to this registry. makeCalibrationCollectionName
(*labels)Make a CALIBRATION collection name appropriate for associating calibration datasets with validity ranges. makeCollectionName
(*labels)Get the instrument-specific collection string to use as derived from the supplied labels. makeCollectionTimestamp
()Create a timestamp string for use in a collection name from the current time. makeCuratedCalibrationRunName
(calibDate, *labels)Make a RUN collection name appropriate for inserting curated calibration datasets with the given CALIBDATE
metadata value.makeDefaultRawIngestRunName
()Make the default instrument-specific run collection string for raw data ingest. makeRefCatCollectionName
(*labels)Return a global (not instrument-specific) name for a collection that holds reference catalogs. makeUmbrellaCollectionName
()Return the name of the umbrella CHAINED
collection for this instrument that combines all standard recommended input collections.makeUnboundedCalibrationRunName
(*labels)Make a RUN collection name appropriate for inserting calibration datasets whose validity ranges are unbounded. register
(registry, *, update)Insert instrument, and other relevant records into Registry
.Attributes Documentation
-
configPaths
= ()¶ Paths to config files to read for specific Tasks.
The paths in this list should contain files of the form
task.py
, for each of the Tasks that requires special configuration.
-
policyName
= None¶ Instrument specific name to use when locating a policy or configuration file in the file system.
Methods Documentation
-
applyConfigOverrides
(name: str, config: Config) → None¶ Apply instrument-specific overrides for a task config.
Parameters: - name :
str
Name of the object being configured; typically the _DefaultName of a Task.
- config :
lsst.pex.config.Config
Config instance to which overrides should be applied.
- name :
-
static
formatCollectionTimestamp
(timestamp: Union[str, datetime.datetime]) → str¶ Format a timestamp for use in a collection name.
Parameters: - timestamp :
str
ordatetime.datetime
Timestamp to format. May be a date or datetime string in extended ISO format (assumed UTC), with or without a timezone specifier, a datetime string in basic ISO format with a timezone specifier, a naive
datetime.datetime
instance (assumed UTC) or a timezone-awaredatetime.datetime
instance (converted to UTC). This is intended to cover all forms that stringCALIBDATE
metadata values have taken in the past, as well as the format this method itself writes out (to enable round-tripping).
Returns: - formatted :
str
Standardized string form for the timestamp.
- timestamp :
-
static
fromName
(name: str, registry: Registry, collection_prefix: Optional[str] = None) → Instrument¶ Given an instrument name and a butler registry, retrieve a corresponding instantiated instrument object.
Parameters: - name :
str
Name of the instrument (must match the return value of
getName
).- registry :
lsst.daf.butler.Registry
Butler registry to query to find the information.
- collection_prefix :
str
, optional Prefix for collection names to use instead of the intrument’s own name. This is primarily for use in simulated-data repositories, where the instrument name may not be necessary and/or sufficient to distinguish between collections.
Returns: - instrument :
Instrument
An instance of the relevant
Instrument
.
Raises: - LookupError
Raised if the instrument is not known to the supplied registry.
- ModuleNotFoundError
Raised if the class could not be imported. This could mean that the relevant obs package has not been setup.
- TypeError
Raised if the class name retrieved is not a string or the imported symbol is not an
Instrument
subclass.
Notes
The instrument must be registered in the corresponding butler.
- name :
-
static
from_string
(name: str, registry: Optional[Registry] = None, collection_prefix: Optional[str] = None) → Instrument¶ Return an instance from the short name or class name.
If the instrument name is not qualified (does not contain a ‘.’) and a butler registry is provided, this will attempt to load the instrument using
Instrument.fromName()
. Otherwise the instrument will be imported and instantiated.Parameters: - name :
str
The name or fully-qualified class name of an instrument.
- registry :
lsst.daf.butler.Registry
, optional Butler registry to query to find information about the instrument, by default
None
.- collection_prefix :
str
, optional Prefix for collection names to use instead of the intrument’s own name. This is primarily for use in simulated-data repositories, where the instrument name may not be necessary and/or sufficient to distinguish between collections.
Returns: - instrument :
Instrument
The instantiated instrument.
Raises: - RuntimeError
Raised if the instrument can not be imported, instantiated, or obtained from the registry.
- TypeError
Raised if the instrument is not a subclass of
Instrument
.
See also
- name :
-
classmethod
getName
() → str¶ Return the short (dimension) name for this instrument.
This is not (in general) the same as the class name - it’s what is used as the value of the “instrument” field in data IDs, and is usually an abbreviation of the full name.
-
getRawFormatter
(dataId: Union[lsst.daf.butler.core.dimensions._coordinate.DataCoordinate, Mapping[str, Any]]) → Type[lsst.daf.butler.core.formatter.Formatter]¶ Return the Formatter class that should be used to read a particular raw file.
Parameters: - dataId :
DataId
Dimension-based ID for the raw file or files being ingested.
Returns: - formatter :
lsst.daf.butler.Formatter
class Class to be used that reads the file into the correct Python object for the raw data.
- dataId :
-
static
importAll
(registry: Registry) → None¶ Import all the instruments known to this registry.
This will ensure that all metadata translators have been registered.
Parameters: - registry :
lsst.daf.butler.Registry
Butler registry to query to find the information.
Notes
It is allowed for a particular instrument class to fail on import. This might simply indicate that a particular obs package has not been setup.
- registry :
-
makeCalibrationCollectionName
(*labels) → str¶ Make a CALIBRATION collection name appropriate for associating calibration datasets with validity ranges.
Parameters: - *labels :
str
Strings to be appended to the base name, using the default delimiter for collection names. Usually this is the name of the ticket on which the calibration collection is being created.
Returns: - name :
str
Calibration collection name.
- *labels :
-
makeCollectionName
(*labels) → str¶ Get the instrument-specific collection string to use as derived from the supplied labels.
Parameters: - *labels :
str
Strings to be combined with the instrument name to form a collection name.
Returns: - name :
str
Collection name to use that includes the instrument’s recommended prefix.
- *labels :
-
static
makeCollectionTimestamp
() → str¶ Create a timestamp string for use in a collection name from the current time.
Returns: - formatted :
str
Standardized string form of the current time.
- formatted :
-
makeCuratedCalibrationRunName
(calibDate: str, *labels) → str¶ Make a RUN collection name appropriate for inserting curated calibration datasets with the given
CALIBDATE
metadata value.Parameters: Returns: - name :
str
Run collection name.
- name :
-
makeDefaultRawIngestRunName
() → str¶ Make the default instrument-specific run collection string for raw data ingest.
Returns: - coll :
str
Run collection name to be used as the default for ingestion of raws.
- coll :
-
static
makeRefCatCollectionName
(*labels) → str¶ Return a global (not instrument-specific) name for a collection that holds reference catalogs.
With no arguments, this returns the name of the collection that holds all reference catalogs (usually a
CHAINED
collection, at least in long-lived repos that may contain more than one reference catalog).Parameters: - *labels :
str
Strings to be added to the global collection name, in order to define a collection name for one or more reference catalogs being ingested at the same time.
Returns: - name :
str
Collection name.
Notes
This is a
staticmethod
, not aclassmethod
, because it should be the same for all instruments.- *labels :
-
makeUmbrellaCollectionName
() → str¶ Return the name of the umbrella
CHAINED
collection for this instrument that combines all standard recommended input collections.This method should almost never be overridden by derived classes.
Returns: - name :
str
Name for the umbrella collection.
- name :
-
makeUnboundedCalibrationRunName
(*labels) → str¶ Make a RUN collection name appropriate for inserting calibration datasets whose validity ranges are unbounded.
Parameters: - *labels :
str
Extra strings to be included in the base name, using the default delimiter for collection names. Usually this is the name of the ticket on which the calibration collection is being created.
Returns: - name :
str
Run collection name.
- *labels :
-
register
(registry: Registry, *, update: bool = False) → None¶ Insert instrument, and other relevant records into
Registry
.Parameters: - registry :
lsst.daf.butler.Registry
Registry client for the data repository to modify.
- update :
bool
, optional If
True
(False
is default), update existing records if they differ from the new ones.
Raises: - lsst.daf.butler.registry.ConflictingDefinitionError
Raised if any existing record has the same key but a different definition as one being registered.
Notes
New records can always be added by calling this method multiple times, as long as no existing records have changed (if existing records have changed,
update=True
must be used). Old records can never be removed by this method.Implementations should guarantee that registration is atomic (the registry should not be modified if any error occurs) and idempotent at the level of individual dimension entries; new detectors and filters should be added, but changes to any existing record should not be. This can generally be achieved via a block like
with registry.transaction(): registry.syncDimensionData("instrument", ...) registry.syncDimensionData("detector", ...) self.registerFilters(registry)
- registry :
- collection_prefix :