PhotodiodeCorrection¶
-
class
lsst.ip.isr.
PhotodiodeCorrection
(table=None, **kwargs)¶ Bases:
lsst.ip.isr.IsrCalib
Parameter set for photodiode correction.
These parameters are included in cameraGeom.Amplifier, but should be accessible externally to allow for testing.
Parameters: - table :
numpy.array
, optional Lookup table; a 2-dimensional array of floats:
- one row for each row index (value of coef[0] in the amplifier)
- one column for each image value.
To avoid copying the table the last index should vary fastest (numpy default “C” order)
- log :
logging.Logger
, optional Logger to handle messages.
- kwargs :
dict
, optional Other keyword arguments to pass to the parent init.
Raises: - RuntimeError
Raised if the supplied table is not 2D, or if the table has fewer columns than rows (indicating that the indices are swapped).
Notes
The photodiode correction attributes stored are: abscissaCorrections :
dict
: [str
,float
] Correction value indexed by exposure pairAttributes Summary
requiredAttributes
Methods Summary
apply
(target)Method to apply the calibration to the target object. calibInfoFromDict
(dictionary)Handle common keywords. determineCalibClass
(metadata, message)Attempt to find calibration class in metadata. fromDetector
(detector)Modify the calibration parameters to match the supplied detector. fromDict
(dictionary)Construct a PhotodiodeCorrection from a dictionary of properties. fromTable
(tableList)Construct calibration from a list of tables. getMetadata
()Retrieve metadata associated with this calibration. readFits
(filename, **kwargs)Read calibration data from a FITS file. readText
(filename, **kwargs)Read calibration representation from a yaml/ecsv file. setMetadata
(metadata)Store a copy of the supplied metadata with this calibration. toDict
()Return a dictionary containing the photodiode correction properties. toTable
()Construct a list of tables containing the information in this calibration. updateMetadata
([setDate])Update metadata keywords with new values. validate
()Validate photodiode correction writeFits
(filename)Write calibration data to a FITS file. writeText
(filename[, format])Write the calibration data to a text file. Attributes Documentation
-
requiredAttributes
¶
Methods Documentation
-
apply
(target)¶ Method to apply the calibration to the target object.
Parameters: - target :
object
Thing to validate against.
Returns: - valid :
bool
Returns true if the calibration was applied correctly.
Raises: - NotImplementedError
Raised if not implemented.
- target :
-
calibInfoFromDict
(dictionary)¶ Handle common keywords.
This isn’t an ideal solution, but until all calibrations expect to find everything in the metadata, they still need to search through dictionaries.
Parameters: - dictionary :
dict
orlsst.daf.base.PropertyList
Source for the common keywords.
Raises: - RuntimeError
Raised if the dictionary does not match the expected OBSTYPE.
- dictionary :
-
classmethod
determineCalibClass
(metadata, message)¶ Attempt to find calibration class in metadata.
Parameters: Returns: - calibClass :
object
The class to use to read the file contents. Should be an
lsst.ip.isr.IsrCalib
subclass.
Raises: - ValueError
Raised if the resulting calibClass is the base
lsst.ip.isr.IsrClass
(which does not implement the content methods).
- calibClass :
-
fromDetector
(detector)¶ Modify the calibration parameters to match the supplied detector.
Parameters: - detector :
lsst.afw.cameraGeom.Detector
Detector to use to set parameters from.
Raises: - NotImplementedError
Raised if not implemented by a subclass. This needs to be implemented by subclasses for each calibration type.
- detector :
-
classmethod
fromDict
(dictionary)¶ Construct a PhotodiodeCorrection from a dictionary of properties.
Parameters: - dictionary :
dict
Dictionary of properties.
Returns: - calib :
lsst.ip.isr.PhotodiodeCorrection
Constructed photodiode data.
Raises: - RuntimeError
Raised if the supplied dictionary is for a different calibration type.
- dictionary :
-
classmethod
fromTable
(tableList)¶ Construct calibration from a list of tables.
This method uses the
fromDict
method to create the calibration after constructing an appropriate dictionary from the input tables.Parameters: - tableList :
list
[astropy.table.Table
] List of tables to use to construct the crosstalk calibration.
Returns: - calib :
lsst.ip.isr.PhotodiodeCorrection
The calibration defined in the tables.
- tableList :
-
getMetadata
()¶ Retrieve metadata associated with this calibration.
Returns: - meta :
lsst.daf.base.PropertyList
Metadata. The returned
PropertyList
can be modified by the caller and the changes will be written to external files.
- meta :
-
classmethod
readFits
(filename, **kwargs)¶ Read calibration data from a FITS file.
Parameters: Returns: - calib :
lsst.ip.isr.IsrCalib
Calibration contained within the file.
- calib :
-
classmethod
readText
(filename, **kwargs)¶ Read calibration representation from a yaml/ecsv file.
Parameters: Returns: - calib :
IsrCalibType
Calibration class.
Raises: - RuntimeError
Raised if the filename does not end in “.ecsv” or “.yaml”.
- calib :
-
setMetadata
(metadata)¶ Store a copy of the supplied metadata with this calibration.
Parameters: - metadata :
lsst.daf.base.PropertyList
Metadata to associate with the calibration. Will be copied and overwrite existing metadata.
- metadata :
-
toDict
()¶ Return a dictionary containing the photodiode correction properties.
The dictionary should be able to be round-tripped through.
fromDict
.Returns: - dictionary :
dict
Dictionary of properties.
- dictionary :
-
toTable
()¶ Construct a list of tables containing the information in this calibration.
The list of tables should create an identical calibration after being passed to this class’s fromTable method.
Returns: - tableList :
list
[astropy.table.Table
] List of tables containing the photodiode correction information.
- tableList :
-
updateMetadata
(setDate=False, **kwargs)¶ Update metadata keywords with new values.
This calls the base class’s method after ensuring the required calibration keywords will be saved.
Parameters: - setDate :
bool
, optional Update the CALIBDATE fields in the metadata to the current time. Defaults to False.
- kwargs
Other keyword parameters to set in the metadata.
- setDate :
-
validate
()¶ Validate photodiode correction
-
writeFits
(filename)¶ Write calibration data to a FITS file.
Parameters: - filename :
str
Filename to write data to.
Returns: - used :
str
The name of the file used to write the data.
- filename :
-
writeText
(filename, format='auto')¶ Write the calibration data to a text file.
Parameters: Returns: - used :
str
The name of the file used to write the data. This may differ from the input if the format is explicitly chosen.
Raises: - RuntimeError
Raised if filename does not end in a known extension, or if all information cannot be written.
Notes
The file is written to YAML/ECSV format and will include any associated metadata.
- used :
- table :