PhotodiodeCorrection¶
- class lsst.ip.isr.PhotodiodeCorrection(table=None, **kwargs)¶
- Bases: - IsrCalib- Parameter set for photodiode correction. - These parameters are included in cameraGeom.Amplifier, but should be accessible externally to allow for testing. - Parameters:
- tablenumpy.array, optional
- Lookup table; a 2-dimensional array of floats: - one row for each row index (value of coef[0] in the amplifier) 
- one column for each image value. 
 - To avoid copying the table the last index should vary fastest (numpy default “C” order) 
- loglogging.Logger, optional
- Logger to handle messages. 
- kwargsdict, optional
- Other keyword arguments to pass to the parent init. 
 
- table
- Raises:
- RuntimeError
- Raised if the supplied table is not 2D, or if the table has fewer columns than rows (indicating that the indices are swapped). 
 
 - Notes - The photodiode correction attributes stored are: abscissaCorrections : - dict: [- str,- float] Correction value indexed by exposure pair- Attributes Summary - Methods Summary - apply(target)- Method to apply the calibration to the target object. - calibInfoFromDict(dictionary)- Handle common keywords. - determineCalibClass(metadata, message)- Attempt to find calibration class in metadata. - fromDetector(detector)- Modify the calibration parameters to match the supplied detector. - fromDict(dictionary)- Construct a PhotodiodeCorrection from a dictionary of properties. - fromTable(tableList)- Construct calibration from a list of tables. - Retrieve metadata associated with this calibration. - readFits(filename, **kwargs)- Read calibration data from a FITS file. - readText(filename, **kwargs)- Read calibration representation from a yaml/ecsv file. - setMetadata(metadata)- Store a copy of the supplied metadata with this calibration. - toDict()- Return a dictionary containing the photodiode correction properties. - toTable()- Construct a list of tables containing the information in this calibration. - updateMetadata([setDate])- Update metadata keywords with new values. - updateMetadataFromExposures(exposures)- Extract and unify metadata information. - validate()- Validate photodiode correction - writeFits(filename)- Write calibration data to a FITS file. - writeText(filename[, format])- Write the calibration data to a text file. - Attributes Documentation - requiredAttributes¶
 - Methods Documentation - apply(target)¶
- Method to apply the calibration to the target object. 
 - calibInfoFromDict(dictionary)¶
- Handle common keywords. - This isn’t an ideal solution, but until all calibrations expect to find everything in the metadata, they still need to search through dictionaries. - Parameters:
- dictionarydictorlsst.daf.base.PropertyList
- Source for the common keywords. 
 
- dictionary
- Raises:
- RuntimeError
- Raised if the dictionary does not match the expected OBSTYPE. 
 
 
 - classmethod determineCalibClass(metadata, message)¶
- Attempt to find calibration class in metadata. - Parameters:
- Returns:
- calibClassobject
- The class to use to read the file contents. Should be an - lsst.ip.isr.IsrCalibsubclass.
 
- calibClass
- Raises:
- ValueError
- Raised if the resulting calibClass is the base - lsst.ip.isr.IsrClass(which does not implement the content methods).
 
 
 - fromDetector(detector)¶
- Modify the calibration parameters to match the supplied detector. - Parameters:
- detectorlsst.afw.cameraGeom.Detector
- Detector to use to set parameters from. 
 
- detector
- Raises:
- NotImplementedError
- Raised if not implemented by a subclass. This needs to be implemented by subclasses for each calibration type. 
 
 
 - classmethod fromDict(dictionary)¶
- Construct a PhotodiodeCorrection from a dictionary of properties. - Parameters:
- dictionarydict
- Dictionary of properties. 
 
- dictionary
- Returns:
- caliblsst.ip.isr.PhotodiodeCorrection
- Constructed photodiode data. 
 
- calib
- Raises:
- RuntimeError
- Raised if the supplied dictionary is for a different calibration type. 
 
 
 - classmethod fromTable(tableList)¶
- Construct calibration from a list of tables. - This method uses the - fromDictmethod to create the calibration after constructing an appropriate dictionary from the input tables.- Parameters:
- tableListlist[astropy.table.Table]
- List of tables to use to construct the crosstalk calibration. 
 
- tableList
- Returns:
- caliblsst.ip.isr.PhotodiodeCorrection
- The calibration defined in the tables. 
 
- calib
 
 - getMetadata()¶
- Retrieve metadata associated with this calibration. - Returns:
- metalsst.daf.base.PropertyList
- Metadata. The returned - PropertyListcan be modified by the caller and the changes will be written to external files.
 
- meta
 
 - classmethod readFits(filename, **kwargs)¶
- Read calibration data from a FITS file. - Parameters:
- Returns:
- caliblsst.ip.isr.IsrCalib
- Calibration contained within the file. 
 
- calib
 
 - classmethod readText(filename, **kwargs)¶
- Read calibration representation from a yaml/ecsv file. - Parameters:
- Returns:
- calibIsrCalibType
- Calibration class. 
 
- calib
- Raises:
- RuntimeError
- Raised if the filename does not end in “.ecsv” or “.yaml”. 
 
 
 - setMetadata(metadata)¶
- Store a copy of the supplied metadata with this calibration. - Parameters:
- metadatalsst.daf.base.PropertyList
- Metadata to associate with the calibration. Will be copied and overwrite existing metadata. 
 
- metadata
 
 - toDict()¶
- Return a dictionary containing the photodiode correction properties. - The dictionary should be able to be round-tripped through. - fromDict.- Returns:
- dictionarydict
- Dictionary of properties. 
 
- dictionary
 
 - toTable()¶
- Construct a list of tables containing the information in this calibration. - The list of tables should create an identical calibration after being passed to this class’s fromTable method. - Returns:
- tableListlist[astropy.table.Table]
- List of tables containing the photodiode correction information. 
 
- tableList
 
 - updateMetadata(setDate=False, **kwargs)¶
- Update metadata keywords with new values. - This calls the base class’s method after ensuring the required calibration keywords will be saved. - Parameters:
- setDatebool, optional
- Update the CALIBDATE fields in the metadata to the current time. Defaults to False. 
- kwargs
- Other keyword parameters to set in the metadata. 
 
- setDate
 
 - updateMetadataFromExposures(exposures)¶
- Extract and unify metadata information. - Parameters:
- exposureslist
- Exposures or other calibrations to scan. 
 
- exposures
 
 - validate()¶
- Validate photodiode correction 
 - writeFits(filename)¶
- Write calibration data to a FITS file. 
 - writeText(filename, format='auto')¶
- Write the calibration data to a text file. - Parameters:
- Returns:
- usedstr
- The name of the file used to write the data. This may differ from the input if the format is explicitly chosen. 
 
- used
- Raises:
- RuntimeError
- Raised if filename does not end in a known extension, or if all information cannot be written. 
 
 - Notes - The file is written to YAML/ECSV format and will include any associated metadata.