IngestIndexedReferenceConfig¶
-
class
lsst.meas.algorithms.
IngestIndexedReferenceConfig
¶ Bases:
lsst.meas.algorithms.ConvertReferenceCatalogConfig
For gen2 backwards compatibility.
Attributes Summary
coord_err_unit
Unit of RA/Dec error fields (astropy.unit.Unit compatible) ( str
, defaultNone
)dataset_config
Configuration for reading the ingested data ( DatasetConfig
, default<class 'lsst.meas.algorithms.ingestIndexReferenceTask.DatasetConfig'>
)dec_err_name
Name of Dec error column ( str
, defaultNone
)dec_name
Name of Dec column (values in decimal degrees) ( str
)epoch_format
Format of epoch column: any value accepted by astropy.time.Time, e.g. epoch_name
Name of epoch column ( str
, defaultNone
)epoch_scale
Scale of epoch column: any value accepted by astropy.time.Time, e.g. extra_col_names
Extra columns to add to the reference catalog. file_reader
Task to use to read the files. history
id_name
Name of column to use as an identifier (optional). is_photometric_name
Name of column stating if satisfactory for photometric calibration (optional). is_resolved_name
Name of column stating if the object is resolved (optional). is_variable_name
Name of column stating if the object is measured to be variable (optional). mag_column_list
The values in the reference catalog are assumed to be in AB magnitudes. mag_err_column_map
A map of magnitude column name (key) to magnitude error column (value). manager
Multiprocessing manager to perform the actual conversion of values, file-by-file. n_processes
Number of python processes to use when ingesting. parallax_err_name
Name of parallax error column ( str
, defaultNone
)parallax_name
Name of parallax column ( str
, defaultNone
)parallax_scale
Scale factor by which to multiply parallax values to obtain units of milliarcsec ( float
, default1.0
)pm_dec_err_name
Name of proper motion Dec error column ( str
, defaultNone
)pm_dec_name
Name of proper motion Dec column ( str
, defaultNone
)pm_ra_err_name
Name of proper motion RA error column ( str
, defaultNone
)pm_ra_name
Name of proper motion RA column ( str
, defaultNone
)pm_scale
Scale factor by which to multiply proper motion values to obtain units of milliarcsec/year ( float
, default1.0
)ra_err_name
Name of RA error column ( str
, defaultNone
)ra_name
Name of RA column (values in decimal degrees) ( str
)Methods Summary
compare
(other[, shortcut, rtol, atol, output])Compare this configuration to another Config
for equality.formatHistory
(name, **kwargs)Format a configuration field’s history to a human-readable format. freeze
()Make this config, and all subconfigs, read-only. items
()Get configurations as (field name, field value)
pairs.iteritems
()Iterate over (field name, field value) pairs. iterkeys
()Iterate over field names itervalues
()Iterate over field values. keys
()Get field names. load
(filename[, root])Modify this config in place by executing the Python code in a configuration file. loadFromStream
(stream[, root, filename])Modify this Config in place by executing the Python code in the provided stream. names
()Get all the field names in the config, recursively. save
(filename[, root])Save a Python script to the named file, which, when loaded, reproduces this config. saveToStream
(outfile[, root, skipImports])Save a configuration file to a stream, which, when loaded, reproduces this config. setDefaults
()Subclass hook for computing defaults. toDict
()Make a dictionary of field names and their values. update
(**kw)Update values of fields specified by the keyword arguments. validate
()Validate the Config, raising an exception if invalid. values
()Get field values. Attributes Documentation
-
dataset_config
¶ Configuration for reading the ingested data (
DatasetConfig
, default<class 'lsst.meas.algorithms.ingestIndexReferenceTask.DatasetConfig'>
)
-
epoch_format
¶ Format of epoch column: any value accepted by astropy.time.Time, e.g. ‘iso’ or ‘unix’ (
str
, defaultNone
)
-
epoch_scale
¶ Scale of epoch column: any value accepted by astropy.time.Time, e.g. ‘utc’ (
str
, defaultNone
)
-
extra_col_names
¶ Extra columns to add to the reference catalog. (
List
, default[]
)
-
file_reader
¶ Task to use to read the files. Default is to expect text files. (
ConfigurableInstance
, default<class 'lsst.meas.algorithms.readTextCatalogTask.ReadTextCatalogConfig'>
)
-
history
¶
-
is_photometric_name
¶ Name of column stating if satisfactory for photometric calibration (optional). (
str
, defaultNone
)
-
is_variable_name
¶ Name of column stating if the object is measured to be variable (optional). (
str
, defaultNone
)
-
mag_column_list
¶ The values in the reference catalog are assumed to be in AB magnitudes. List of column names to use for photometric information. At least one entry is required. (
List
)
-
mag_err_column_map
¶ A map of magnitude column name (key) to magnitude error column (value). (
Dict
, default{}
)
-
manager
¶ Multiprocessing manager to perform the actual conversion of values, file-by-file. (
ConfigurableInstance
, default<class 'lsst.meas.algorithms.convertRefcatManager.ConvertRefcatManagerConfig'>
)
-
parallax_scale
¶ Scale factor by which to multiply parallax values to obtain units of milliarcsec (
float
, default1.0
)
-
pm_scale
¶ Scale factor by which to multiply proper motion values to obtain units of milliarcsec/year (
float
, default1.0
)
Methods Documentation
-
compare
(other, shortcut=True, rtol=1e-08, atol=1e-08, output=None)¶ Compare this configuration to another
Config
for equality.Parameters: - other :
lsst.pex.config.Config
Other
Config
object to compare against this config.- shortcut :
bool
, optional If
True
, return as soon as an inequality is found. Default isTrue
.- rtol :
float
, optional Relative tolerance for floating point comparisons.
- atol :
float
, optional Absolute tolerance for floating point comparisons.
- output : callable, optional
A callable that takes a string, used (possibly repeatedly) to report inequalities.
Returns: - isEqual :
bool
True
when the twolsst.pex.config.Config
instances are equal.False
if there is an inequality.
See also
Notes
Unselected targets of
RegistryField
fields and unselected choices ofConfigChoiceField
fields are not considered by this method.Floating point comparisons are performed by
numpy.allclose
.- other :
-
formatHistory
(name, **kwargs)¶ Format a configuration field’s history to a human-readable format.
Parameters: - name :
str
Name of a
Field
in this config.- kwargs
Keyword arguments passed to
lsst.pex.config.history.format
.
Returns: - history :
str
A string containing the formatted history.
See also
- name :
-
freeze
()¶ Make this config, and all subconfigs, read-only.
-
items
()¶ Get configurations as
(field name, field value)
pairs.Returns: - items :
list
List of tuples for each configuration. Tuple items are:
- Field name.
- Field value.
See also
- items :
-
iteritems
()¶ Iterate over (field name, field value) pairs.
Yields: - item :
tuple
Tuple items are:
- Field name.
- Field value.
See also
- item :
-
itervalues
()¶ Iterate over field values.
Yields: - value : obj
A field value.
See also
-
keys
()¶ Get field names.
Returns: - names :
list
List of
lsst.pex.config.Field
names.
See also
- names :
-
load
(filename, root='config')¶ Modify this config in place by executing the Python code in a configuration file.
Parameters: - filename :
str
Name of the configuration file. A configuration file is Python module.
- root :
str
, optional Name of the variable in file that refers to the config being overridden.
For example, the value of root is
"config"
and the file contains:config.myField = 5
Then this config’s field
myField
is set to5
.Deprecated: For backwards compatibility, older config files that use
root="root"
instead ofroot="config"
will be loaded with a warning printed tosys.stderr
. This feature will be removed at some point.
See also
lsst.pex.config.Config.loadFromStream
,lsst.pex.config.Config.save
,lsst.pex.config.Config.saveFromStream
- filename :
-
loadFromStream
(stream, root='config', filename=None)¶ Modify this Config in place by executing the Python code in the provided stream.
Parameters: - stream : file-like object,
str
, or compiled string Stream containing configuration override code.
- root :
str
, optional Name of the variable in file that refers to the config being overridden.
For example, the value of root is
"config"
and the file contains:config.myField = 5
Then this config’s field
myField
is set to5
.Deprecated: For backwards compatibility, older config files that use
root="root"
instead ofroot="config"
will be loaded with a warning printed tosys.stderr
. This feature will be removed at some point.- filename :
str
, optional Name of the configuration file, or
None
if unknown or contained in the stream. Used for error reporting.
See also
lsst.pex.config.Config.load
,lsst.pex.config.Config.save
,lsst.pex.config.Config.saveFromStream
- stream : file-like object,
-
names
()¶ Get all the field names in the config, recursively.
Returns:
-
save
(filename, root='config')¶ Save a Python script to the named file, which, when loaded, reproduces this config.
Parameters: - filename :
str
Desination filename of this configuration.
- root :
str
, optional Name to use for the root config variable. The same value must be used when loading (see
lsst.pex.config.Config.load
).
- filename :
-
saveToStream
(outfile, root='config', skipImports=False)¶ Save a configuration file to a stream, which, when loaded, reproduces this config.
Parameters: - outfile : file-like object
Destination file object write the config into. Accepts strings not bytes.
- root
Name to use for the root config variable. The same value must be used when loading (see
lsst.pex.config.Config.load
).- skipImports :
bool
, optional If
True
then do not includeimport
statements in output, this is to support human-oriented output frompipetask
where additional clutter is not useful.
-
setDefaults
()¶ Subclass hook for computing defaults.
Notes
Derived
Config
classes that must compute defaults rather than using theField
instances’s defaults should do so here. To correctly use inherited defaults, implementations ofsetDefaults
must call their base class’ssetDefaults
.
-
toDict
()¶ Make a dictionary of field names and their values.
Returns: See also
Notes
This method uses the
toDict
method of individual fields. Subclasses ofField
may need to implement atoDict
method for this method to work.
-
update
(**kw)¶ Update values of fields specified by the keyword arguments.
Parameters: - kw
Keywords are configuration field names. Values are configuration field values.
Notes
The
__at
and__label
keyword arguments are special internal keywords. They are used to strip out any internal steps from the history tracebacks of the config. Do not modify these keywords to subvert aConfig
instance’s history.Examples
This is a config with three fields:
>>> from lsst.pex.config import Config, Field >>> class DemoConfig(Config): ... fieldA = Field(doc='Field A', dtype=int, default=42) ... fieldB = Field(doc='Field B', dtype=bool, default=True) ... fieldC = Field(doc='Field C', dtype=str, default='Hello world') ... >>> config = DemoConfig()
These are the default values of each field:
>>> for name, value in config.iteritems(): ... print(f"{name}: {value}") ... fieldA: 42 fieldB: True fieldC: 'Hello world'
Using this method to update
fieldA
andfieldC
:>>> config.update(fieldA=13, fieldC='Updated!')
Now the values of each field are:
>>> for name, value in config.iteritems(): ... print(f"{name}: {value}") ... fieldA: 13 fieldB: True fieldC: 'Updated!'
-
validate
()¶ Validate the Config, raising an exception if invalid.
Raises: - lsst.pex.config.FieldValidationError
Raised if verification fails.
Notes
The base class implementation performs type checks on all fields by calling their
validate
methods.Complex single-field validation can be defined by deriving new Field types. For convenience, some derived
lsst.pex.config.Field
-types (ConfigField
andConfigChoiceField
) are defined inlsst.pex.config
that handle recursing into subconfigs.Inter-field relationships should only be checked in derived
Config
classes after calling this method, and base validation is complete.
-