LatissTranslator¶
-
class
lsst.obs.lsst.translators.
LatissTranslator
(header, filename=None)¶ Bases:
lsst.obs.lsst.translators.lsst.LsstBaseTranslator
Metadata translator for LSST LATISS data from AuxTel.
For lab measurements many values are masked out.
Attributes Summary
DETECTOR_GROUP_NAME
Fixed name of detector group. DETECTOR_MAX
Maximum number of detectors to use when calculating the detector_exposure_id. DETECTOR_NAME
Fixed name of single sensor. cameraPolicyFile
default_resource_package
default_resource_root
default_search_path
detectorMapping
detectorSerials
name
Name of this translation class supported_instrument
Supports the LATISS instrument. translators
Methods Summary
are_keys_ok
(keywords)Are the supplied keys all present and defined? can_translate
(header[, filename])Indicate whether this translation class can translate the supplied header. can_translate_with_options
(header, options)Helper method for can_translate
allowing options.cards_used
()Cards used during metadata extraction. compute_detector_exposure_id
(exposure_id, …)Compute the detector exposure ID from detector number and exposure ID. compute_detector_info_from_serial
(…)Helper method to return the detector information from the serial. compute_detector_num_from_name
(…)Helper method to return the detector number from the name. compute_exposure_id
(dayobs, seqnum[, controller])Helper method to calculate the exposure_id. defined_in_this_class
(name)Report if the specified class attribute is defined specifically in this class. detector_mapping
()Returns the mapping of full name to detector ID and serial. detector_serials
()Obtain the mapping of detector serial to detector group, name, and number. determine_translator
(header[, filename])Determine a translation class by examining the header fix_header
(header, instrument, obsid[, filename])Fix an incorrect LATISS header. is_key_ok
(keyword)Return True
if the value associated with the named keyword is present in this header and defined.is_keyword_defined
(header, keyword)Return True
if the value associated with the named keyword is present in the supplied header and defined.is_on_sky
()Determine if this is an on-sky observation. max_detector_exposure_id
()The maximum detector exposure ID expected to be generated by this instrument. max_exposure_id
()The maximum exposure ID expected from this instrument. quantity_from_card
(keywords, unit[, …])Calculate a Astropy Quantity from a header card and a unit. resource_root
()Package resource to use to locate correction resources within an installed package. search_paths
()Search paths to use for LSST data when looking for header correction files. to_altaz_begin
()to_boresight_airmass
()Calculate airmass at boresight at start of observation. to_boresight_rotation_angle
()Angle of the instrument in boresight_rotation_coord frame. to_boresight_rotation_coord
()Boresight rotation angle. to_dark_time
()to_datetime_begin
()to_datetime_end
()to_detector_exposure_id
()to_detector_group
()Collection name of which this detector is a part. to_detector_name
()Name of the detector within the instrument (might not be unique if there are detector groups). to_detector_num
()Unique (for instrument) integer identifier for the sensor. to_detector_serial
()Serial number/string associated with this detector. to_detector_unique_name
()Return a unique name for the detector. to_exposure_group
()Calculate the exposure group string. to_exposure_id
()Generate a unique exposure ID number to_exposure_time
()to_instrument
()The instrument used to observe the exposure. to_location
()to_object
()Object of interest or field name. to_observation_counter
()Return the sequence number within the observing day. to_observation_id
()Label uniquely identifying this observation (can be related to ‘exposure_id’). to_observation_reason
()to_observation_type
()Determine the observation type. to_observing_day
()Return the day of observation as YYYYMMDD integer. to_physical_filter
()Calculate the physical filter name. to_pressure
()Atmospheric pressure outside the dome. to_relative_humidity
()Relative humidity outside the dome. to_science_program
()Observing program (survey or proposal) identifier. to_telescope
()Full name of the telescope. to_temperature
()Temperature outside the dome. to_tracking_radec
()to_visit_id
()Calculate the visit associated with this exposure. validate_value
(value, default[, minimum, …])Validate the supplied value, returning a new value if out of range Attributes Documentation
-
DETECTOR_GROUP_NAME
= 'RXX'¶ Fixed name of detector group.
-
DETECTOR_MAX
= 0¶ Maximum number of detectors to use when calculating the detector_exposure_id.
-
DETECTOR_NAME
= 'S00'¶ Fixed name of single sensor.
-
cameraPolicyFile
= None¶
-
default_resource_package
= 'astro_metadata_translator'¶
-
default_resource_root
= None¶
-
default_search_path
= None¶
-
detectorMapping
= None¶
-
detectorSerials
= None¶
-
name
= 'LSST_LATISS'¶ Name of this translation class
-
supported_instrument
= 'LATISS'¶ Supports the LATISS instrument.
-
translators
= {'DECam': <class 'astro_metadata_translator.translators.decam.DecamTranslator'>, 'HSC': <class 'astro_metadata_translator.translators.hsc.HscTranslator'>, 'LSST-TS3': <class 'lsst.obs.lsst.translators.ts3.LsstTS3Translator'>, 'LSST-TS8': <class 'lsst.obs.lsst.translators.ts8.LsstTS8Translator'>, 'LSST-UCDCam': <class 'lsst.obs.lsst.translators.lsst_ucdcam.LsstUCDCamTranslator'>, 'LSSTCam': <class 'lsst.obs.lsst.translators.lsstCam.LsstCamTranslator'>, 'LSSTCam-PhoSim': <class 'lsst.obs.lsst.translators.phosim.LsstCamPhoSimTranslator'>, 'LSSTCam-imSim': <class 'lsst.obs.lsst.translators.imsim.LsstCamImSimTranslator'>, 'LSSTComCam': <class 'lsst.obs.lsst.translators.comCam.LsstComCamTranslator'>, 'LSST_LATISS': <class 'lsst.obs.lsst.translators.latiss.LatissTranslator'>, 'MegaPrime': <class 'astro_metadata_translator.translators.megaprime.MegaPrimeTranslator'>, 'SDSS': <class 'astro_metadata_translator.translators.sdss.SdssTranslator'>, 'SuprimeCam': <class 'astro_metadata_translator.translators.suprimecam.SuprimeCamTranslator'>}¶
Methods Documentation
-
are_keys_ok
(keywords)¶ Are the supplied keys all present and defined?
Parameters: - keywords : iterable of
str
Keywords to test.
Returns: - keywords : iterable of
-
classmethod
can_translate
(header, filename=None)¶ Indicate whether this translation class can translate the supplied header.
Parameters: Returns:
-
classmethod
can_translate_with_options
(header, options, filename=None)¶ Helper method for
can_translate
allowing options.Parameters: - header :
dict
-like Header to convert to standardized form.
- options :
dict
Headers to try to determine whether this header can be translated by this class. If a card is found it will be compared with the expected value and will return that comparison. Each card will be tried in turn until one is found.
- filename :
str
, optional Name of file being translated.
Returns: Notes
Intended to be used from within
can_translate
implementations for specific translators. Is not intended to be called directly fromdetermine_translator
.- header :
-
cards_used
()¶ Cards used during metadata extraction.
Returns:
-
static
compute_detector_exposure_id
(exposure_id, detector_num)¶ Compute the detector exposure ID from detector number and exposure ID.
This is a helper method to allow code working outside the translator infrastructure to use the same algorithm.
Parameters: Returns: - detector_exposure_id :
int
The calculated ID.
- detector_exposure_id :
-
classmethod
compute_detector_info_from_serial
(detector_serial)¶ Helper method to return the detector information from the serial.
Parameters: - detector_serial :
str
Detector serial ID.
Returns: - detector_serial :
-
classmethod
compute_detector_num_from_name
(detector_group, detector_name)¶ Helper method to return the detector number from the name.
Parameters: Returns: - num :
int
Detector number.
- num :
-
static
compute_exposure_id
(dayobs, seqnum, controller=None)¶ Helper method to calculate the exposure_id.
Parameters: - dayobs :
str
Day of observation in either YYYYMMDD or YYYY-MM-DD format. If the string looks like ISO format it will be truncated before the
T
before being handled.- seqnum :
int
orstr
Sequence number.
- controller :
str
, optional Controller to use. If this is “O”, no change is made to the exposure ID. If it is “C” a 1000 is added to the year component of the exposure ID.
None
indicates that the controller is not relevant to the exposure ID calculation (generally this is the case for test stand data).
Returns: - exposure_id :
int
Exposure ID in form YYYYMMDDnnnnn form.
- dayobs :
-
classmethod
defined_in_this_class
(name)¶ Report if the specified class attribute is defined specifically in this class.
Parameters: - name :
str
Name of the attribute to test.
Returns: - in_class :
bool
True
if there is a attribute of that name defined in this specific subclass.False
if the method is not defined in this specific subclass but is defined in a parent class. ReturnsNone
if the attribute is not defined anywhere in the class hierarchy (which can happen if translators have typos in their mapping tables).
Notes
Retrieves the attribute associated with the given name. Then looks in all the parent classes to determine whether that attribute comes from a parent class or from the current class. Attributes are compared using
id()
.- name :
-
classmethod
detector_mapping
()¶ Returns the mapping of full name to detector ID and serial.
Returns: Raises: - ValueError
Raised if no camera policy file has been registered with this translation class.
Notes
Will construct the mapping if none has previously been constructed.
-
classmethod
detector_serials
()¶ Obtain the mapping of detector serial to detector group, name, and number.
Returns:
-
classmethod
determine_translator
(header, filename=None)¶ Determine a translation class by examining the header
Parameters: Returns: - translator :
MetadataTranslator
Translation class that knows how to extract metadata from the supplied header.
Raises: - ValueError
None of the registered translation classes understood the supplied header.
- translator :
-
classmethod
fix_header
(header, instrument, obsid, filename=None)¶ Fix an incorrect LATISS header.
Parameters: - header :
dict
The header to update. Updates are in place.
- instrument :
str
The name of the instrument.
- obsid :
str
Unique observation identifier associated with this header. Will always be provided.
- filename :
str
, optional Filename associated with this header. May not be set since headers can be fixed independently of any filename being known.
Returns: - modified = `bool`
Returns
True
if the header was updated.
Notes
This method does not apply per-obsid corrections. The following corrections are applied:
- On June 24th 2019 the detector was changed from ITL-3800C-098 to ITL-3800C-068. The header is intended to be correct in the future.
- In late 2019 the DATE-OBS and MJD-OBS headers were reporting 1970 dates. To correct, the DATE/MJD headers are copied in to replace them and the -END headers are cleared.
- Until November 2019 the IMGTYPE was set in the GROUPID header. The value is moved to IMGTYPE.
- SHUTTIME is always forced to be
None
.
Corrections are reported as debug level log messages.
See
fix_header
for details of the general process.- header :
-
is_key_ok
(keyword)¶ Return
True
if the value associated with the named keyword is present in this header and defined.Parameters: - keyword :
str
Keyword to check against header.
Returns: - keyword :
-
static
is_keyword_defined
(header, keyword)¶ Return
True
if the value associated with the named keyword is present in the supplied header and defined.Parameters: Returns:
-
is_on_sky
()¶ Determine if this is an on-sky observation.
Returns: - is_on_sky :
bool
Returns True if this is a observation on sky on the summit.
- is_on_sky :
-
classmethod
max_detector_exposure_id
()¶ The maximum detector exposure ID expected to be generated by this instrument.
Returns: - max_id :
int
The maximum value.
- max_id :
-
classmethod
max_exposure_id
()¶ The maximum exposure ID expected from this instrument.
Returns: - max_exposure_id :
int
The maximum value.
- max_exposure_id :
-
quantity_from_card
(keywords, unit, default=None, minimum=None, maximum=None, checker=None)¶ Calculate a Astropy Quantity from a header card and a unit.
Parameters: - keywords :
str
orlist
ofstr
Keyword to use from header. If a list each keyword will be tried in turn until one matches.
- unit :
astropy.units.UnitBase
Unit of the item in the header.
- default :
float
, optional Default value to use if the header value is invalid. Assumed to be in the same units as the value expected in the header. If None, no default value is used.
- minimum :
float
, optional Minimum possible valid value, optional. If the calculated value is below this value, the default value will be used.
- maximum :
float
, optional Maximum possible valid value, optional. If the calculated value is above this value, the default value will be used.
- checker :
function
, optional Callback function to be used by the translator method in case the keyword is not present. Function will be executed as if it is a method of the translator class. Running without raising an exception will allow the default to be used. Should usually raise
KeyError
.
Returns: - q :
astropy.units.Quantity
Quantity representing the header value.
Raises: - KeyError
The supplied header key is not present.
- keywords :
-
resource_root
()¶ Package resource to use to locate correction resources within an installed package.
Returns:
-
search_paths
()¶ Search paths to use for LSST data when looking for header correction files.
Returns: - path :
list
List with a single element containing the full path to the
corrections
directory within theobs_lsst
package.
- path :
-
to_altaz_begin
()¶
-
to_boresight_airmass
()¶ Calculate airmass at boresight at start of observation.
Notes
Early data are missing AMSTART header so we fall back to calculating it from ELSTART.
-
to_boresight_rotation_angle
()¶ Angle of the instrument in boresight_rotation_coord frame.
Returns: - translation :
astropy.coordinates.Angle
Translated value derived from the header.
- translation :
-
to_boresight_rotation_coord
()¶ Boresight rotation angle.
Only relevant for science observations.
-
to_dark_time
()¶
-
to_datetime_begin
()¶
-
to_datetime_end
()¶
-
to_detector_exposure_id
()¶
-
to_detector_group
()¶ Collection name of which this detector is a part. Can be None if there are no detector groupings.
Returns: - translation :
str
Translated property.
- translation :
-
to_detector_name
()¶ Name of the detector within the instrument (might not be unique if there are detector groups).
Returns: - translation :
str
Translated property.
- translation :
-
to_detector_num
()¶ Unique (for instrument) integer identifier for the sensor.
Returns: - translation :
int
Translated property.
- translation :
-
to_detector_serial
()¶ Serial number/string associated with this detector.
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_detector_unique_name
()¶ Return a unique name for the detector.
Base class implementation attempts to combine
detector_name
withdetector_group
. Group is only used if notNone
.Can be over-ridden by specialist translator class.
Returns: - name :
str
detector_group``_``detector_name
ifdetector_group
is defined, else thedetector_name
is assumed to be unique. If neither return a valid value an exception is raised.
Raises: - NotImplementedError
Raised if neither detector_name nor detector_group is defined.
- name :
-
to_exposure_group
()¶ Calculate the exposure group string.
For LSSTCam and LATISS this is read from the
GROUPID
header. If that header is missing the exposure_id is returned instead as a string.
-
to_exposure_id
()¶ Generate a unique exposure ID number
This is a combination of DAYOBS and SEQNUM, and optionally CONTRLLR.
Returns: - exposure_id :
int
Unique exposure number.
- exposure_id :
-
to_exposure_time
()¶
-
to_instrument
()¶ The instrument used to observe the exposure.
Returns: - translation :
str
Translated property.
- translation :
-
to_location
()¶
-
to_object
()¶ Object of interest or field name.
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_observation_counter
()¶ Return the sequence number within the observing day.
Returns: - counter :
int
The sequence number for this day.
- counter :
-
to_observation_id
()¶ Label uniquely identifying this observation (can be related to ‘exposure_id’).
Returns: - translation :
str
Translated value derived from the header.
- translation :
-
to_observation_reason
()¶
-
to_observation_type
()¶ Determine the observation type.
In the absence of an
IMGTYPE
header, assumes lab data is always a dark if exposure time is non-zero, else bias.Returns: - obstype :
str
Observation type.
- obstype :
-
to_observing_day
()¶ Return the day of observation as YYYYMMDD integer.
For LSSTCam and other compliant instruments this is the value of the DAYOBS header.
Returns: - obs_day :
int
The day of observation.
- obs_day :
-
to_physical_filter
()¶ Calculate the physical filter name.
Returns: - filter :
str
Name of filter. A combination of FILTER and GRATING headers joined by a “~”. The filter and grating are always combined. The filter or grating part will be “none” if no value is specified. Uses “empty” if any of the filters or gratings indicate an “empty_N” name. “unknown” indicates that the filter is not defined anywhere but we think it should be. “none” indicates that the filter was not defined but the observation is a dark or bias.
- filter :
-
to_pressure
()¶ Atmospheric pressure outside the dome.
Returns: - translation :
astropy.units.Quantity
Translated property.
- translation :
-
to_relative_humidity
()¶ Relative humidity outside the dome.
Returns: - translation :
float
Translated property.
- translation :
-
to_science_program
()¶ Observing program (survey or proposal) identifier.
Returns: - translation :
str
Translated property.
- translation :
-
to_temperature
()¶ Temperature outside the dome.
Returns: - translation :
astropy.units.Quantity
Translated property.
- translation :
-
to_tracking_radec
()¶
-
to_visit_id
()¶ Calculate the visit associated with this exposure.
Notes
For LATISS and LSSTCam the default visit is derived from the exposure group. For other instruments we return the exposure_id.
-
static
validate_value
(value, default, minimum=None, maximum=None)¶ Validate the supplied value, returning a new value if out of range
Parameters: - value :
float
Value to be validated.
- default :
float
Default value to use if supplied value is invalid or out of range. Assumed to be in the same units as the value expected in the header.
- minimum :
float
Minimum possible valid value, optional. If the calculated value is below this value, the default value will be used.
- maximum :
float
Maximum possible valid value, optional. If the calculated value is above this value, the default value will be used.
Returns: - value :
float
Either the supplied value, or a default value.
- value :
-