DiaObjectCalculationPlugin¶
-
class
lsst.ap.association.DiaObjectCalculationPlugin(config, name, metadata)¶ Bases:
lsst.meas.base.CatalogCalculationPluginBase class for DIA catalog calculation plugins.
Task follows CatalogCalculationPlugin with modifications for use in AP.
Parameters: - config :
DiaObjectCalculationPlugin.ConfigClass Plugin configuration.
- name :
str The string the plugin was registered with.
- metadata :
lsst.daf.base.PropertySet Plugin metadata that will be attached to the output catalog
Attributes Summary
APCORR_ORDERCENTROID_ORDERDEFAULT_CATALOGCALCULATIONFLUX_MOMENTS_CALCULATEDAdd order after flux means and stds are calculated. FLUX_ORDERSHAPE_ORDERinputColsDiaObject column names required by the plugin in order to run and complete its calculation. outputColsDiaObject column names output by the plugin. plugTypeDoes the plugin operate on a single source or the whole catalog ( str)? If the plugin operates on a single source at a time, this should be set to"single"; if it expects the whoe catalog, to"multi".registryList of available plugins ( lsst.meas.base.PluginRegistry).Methods Summary
calculate(diaObject, diaSources[, …])Perform the calculation specified by this plugin. fail(diaObject, columns[, error])Set diaObject position values to nan. getExecutionOrder()Used to set the relative order of plugin execution. getLogName()getTransformClass()Get the measurement transformation appropriate to this plugin. Attributes Documentation
-
APCORR_ORDER= 3.0¶
-
CENTROID_ORDER= 0.0¶
-
DEFAULT_CATALOGCALCULATION= 4.0¶
-
FLUX_MOMENTS_CALCULATED= 5.0¶ Add order after flux means and stds are calculated.
-
FLUX_ORDER= 2.0¶
-
SHAPE_ORDER= 1.0¶
-
inputCols= []¶ DiaObject column names required by the plugin in order to run and complete its calculation. DiaCalculationTask should raise an error is a plugin is instantiated without the needed column available. Input columns should be defined in the DPDD/cat/Apdb schema. Filter dependent columns should be specified without the filter name perpended to them. eg
PSFluxMeaninstead ofuPSFluxMean.
-
outputCols= []¶ DiaObject column names output by the plugin. DiaCalculationTask should raise an error if another pluging is run output to the same column. Output columns should be defined in the DPDD/cat/Apdb schema. Filter dependent columns should be specified without the filter name perpended to them. eg
PSFluxMeaninstead ofuPSFluxMean.
-
plugType= 'single'¶ Does the plugin operate on a single source or the whole catalog (
str)? If the plugin operates on a single source at a time, this should be set to"single"; if it expects the whoe catalog, to"multi". If the plugin is of type"multi", thefailmethod must be implemented to accept the whole catalog. If the plugin is of type"single",failshould accept a single source record.
-
registry= <lsst.meas.base.pluginRegistry.PluginRegistry object>¶ List of available plugins (
lsst.meas.base.PluginRegistry).
Methods Documentation
-
calculate(diaObject, diaSources, filterDiaFluxes=None, filterName=None, **kwargs)¶ Perform the calculation specified by this plugin.
This method can either be used to operate on a single catalog record or a whole catalog, populating it with the output defined by this plugin.
Note that results may be added to catalog records as new columns, or may result in changes to existing values.
Parameters: - diaObject :
dict Summary object to store values in.
- diaSources :
pandas.DataFrame DataFrame representing all diaSources associated with this diaObject.
- filterDiaFluxes :
pandas.DataFrame DataFrame representing diaSources associated with this diaObject that are observed in the band pass
filterName.- filterName :
str Simple name of the filter for the flux being calculated.
- **kwargs
Any additional keyword arguments that may be passed to the plugin.
- diaObject :
-
fail(diaObject, columns, error=None)¶ Set diaObject position values to nan.
Parameters: - diaObject :
dict Summary object to store values in.
- columns :
listofstr List of string names of columns to write a the failed value.
- error :
BaseExceptionorNone Error to pass. Kept for consistency with CatologCalculationPlugin. Unused.
- diaObject :
-
classmethod
getExecutionOrder()¶ Used to set the relative order of plugin execution.
The values returned by
getExecutionOrderare compared across all plugins, and smaller numbers run first.Notes
CatalogCalculationPlugins must run withBasePlugin.DEFAULT_CATALOGCALCULATIONor higher.All plugins must implement this method with an appropriate run level
-
getLogName()¶
-
static
getTransformClass()¶ Get the measurement transformation appropriate to this plugin.
This returns a subclass of
transforms.MeasurementTransform, which may be instantiated with details of the algorithm configuration and then called with information about calibration and WCS to convert from raw measurement quantities to calibrated units. Calibrated data is then provided in a separate output table.Notes
By default, we copy everything from the input to the output without transformation.
- config :